Annual Fuel Utilization Efficiency. Indicated as a percentage, your furnace’s AFUE tells you how much energy is being converted to heat. For example, an AFUE of 90 means that 90% of the fuel is being used to warm your home, while the other 10% escapes as exhaust with the combustion gases.
British Thermal Unit. Used for both heating and cooling, BTU is a measure of the heat given off when fuel is combusted. Or for cooling, it’s a measure of heat extracted from your home. (One BTU is approximately equal to the heat given off by a wooden kitchen match.)
Stands for Cubic Feet per Minute. A measurement of airflow that indicates how many cubic feet of air pass by a stationary point in one minute. The higher the number, the more air is being forced through the system.
The ability of a heating or cooling system to heat or cool a given amount of space. For heating, this is usually expressed in BTUs. For cooling, it is usually given in tons.
Part of a split-system heat pump or air conditioner’s outdoor unit that controls the pressure applied to the refrigerant, necessary for taking in heat to warm your home with a heat pump or getting rid of heat to keep your home cool.
Part of the outdoor portion of a split-system air conditioner or heat pump. By converting refrigerant that is in a gas form back to a liquid, the coil sends heat carried by the refrigerant to the outside.
A type of “valve” used in duct work that opens or closes to control airflow. Used in zoning to control the amount of warm or cool air entering certain areas of your home.
A type of furnace that takes cool air from the top and blows warm air to the bottom-commonly used where furnaces must be located in a second-floor closet or utility area.
Hollow pipes used to transfer air from the Air Handler to the air vents throughout your home. Ductwork is one of the most important components of a home heating and cooling system.
Energy Efficiency Ratings (EER) measure the efficiency with which a product uses energy to function. It is calcuated by dividing a product’s BTU output by its wattage.
An electronic device that filters out large particles and contaminants in indoor air. It then electronically pulls out tiny particles that have been magnetized, such as viruses and bacteria, drawing them to a collector plate.
Energy Star is a government-backed program helping businesses and individuals protect the environment through superior energy efficiency. Products with the Energy Star rating will be efficient and save cost on energy bills.
Part of a split-system air conditioner or heat pump located indoors. The evaporator coil cools and dehumidifies the air by converting liquid refrigerant into a gas (or vice-versa). A blower moter, typically in a furnace, then moves air over the coil to either heat or cool your home.
An indoor component of an air conditioner or heat pump system, used in place of a furnace and evaporator coil, to provide change the refrigerant from a gas to a liquid (or vice-versa) and blow air over the coil to cool or heat your home.
The Heating Seasonal Performance Factor is a measure of the heating efficiency of a heat pump. The higher the HSPF number, the more efficiently the heat pump heats your home.
A product that works just like an air conditioner in cooling mode; however, in heating mode, the refrigerant flow is reversed and heat is extrated from the outside air too heat your home.
A type of furnace, installed on its “side”, that draws in air from one side, heats it and sends the warm air out the other side. Most often used for installations in attics or crawl spaces
A piece of equipment that adds water vapor to heated air as it moves out of the furnace. This adds necessary moisture to protect your furnishings and reduce static electricity.
Hybrid Heat systems deliver exceptional performance by using a heating source that provides the most energy-efficient comfort during moderate heating conditions.
A series of studies performed to determine the heating or cooling requirements of your home. An energy load analysis uses information such as the square footage of your home, window or door areas, insulation quality and local climate to determine the heating and cooling capacity needed by your furnace, heat pump or air conditioner. When referring to heating, this is often known as a Heat Loss Analysis, since a home’s heating requirements are determined by the amount of heat lost through the roof, entry ways and walls.
The Minimum Efficiency Reporting Value is the standard comparison of the efficiency of an air filter. The MERV scale ranges from 1 (least efficient) to 16 (most efficient), and measures a filter’s ability remove particles from 3 to 10 microns in size.
A heating and cooling system comprised of products that have been certified to perform at promised comfort and efficiency levels when used together, and used according to design and engineering specifications.
Overall measure of the efficiency and value of your home comfort system. By combining your purchase price and ongoing operating costs, a payback analysis determines the number of years required before monthly energy savings offset the purchase price.
Puron® Refrigerant is an environmentally sound refrigerant designed not to harm the earth’s ozone layer. Federal law requires that all manufacturers phase out ozone depleting refrigerants in the next few years. Puron Refrigerant is approved by the US Environmental Protection Agency as a replacement from Freon 22*.
R-22 is a single component HCFC refrigerant with low ozone depletion potential. It has long been used in a variety of air-conditioning and refrigeration applications in a variety of markets. Production of R-22 will cease in 2015 per the Montreal Protocol.
The Seasonal Energy Efficiency Ratio is a measure of the cooling efficiency of your air conditioner or heat pump. The higher the SEER number, the more efficient the system is at converting electricity into cooling power.
A state-of-the-art electronic thermostat with a built-in memory that can be programmed for different temperature settings at different times of the day.
Refers to an air conditioner or heat pump that has components in two locations. Usually, one part of the system is located inside (evaporator coil) and the other is located outside your home (condenser coil).
The Thermidistat™ Control monitors temperatures both inside and outside, as well as indoor humidity and adjusts system operation to maintain the temperature and humidity levels set by the homeowner.
A thermostatic expansion valve (TXV) is precision device used to meter the flow of liquid refrigerant entering the evaporator at a rate that matches the amount of refrigerant being boiled off in the evaporator.
Two Stage Compressors are capable of two levels of operation, a low stage and a high stage. Properly sized equipment will operate 80% of the time in low stage, enhancing efficiency and comfort with lower humidity levels and quieter operation. It’s like getting two air conditioners or heat pumps in one system.
A type of furnace that draws cool air from the bottom and blows the warmed air out the top into the duct work. This type of furnace is usually installed in a basement or an out-of-the-way closet.
A way to increase your home comfort and energy efficiency by controlling when and where heating and cooling occurs in a home. Programmable thermostats are used to control operating times of the equipment. Dampers are used to direct air flow to certain parts or “zones” of the home.
Can out within the week and did a cleaning and fixed some parts that needed replaced. Jerry was very friendly and explained what he was…
David Y.
Great place
Lucinda L.
Mike and I work at Westfield Plaza here in Wilder. We have a unit that has no heat. I asked about space heaters, they loaned…
Bobbie F.
Haven't actually completed a purchase yet, however, staff has been very kind, helpful and professional, and their quoted price appears to be very fair!
Melissa D.
Great service. Technicians were professional and did a great job installing a new HVAC system. Positive Responsiveness, Punctuality, Quality, Professionalism, Value Services Installation, Heating system…